Abstract: The distribution of energy consumption in ethylbenzene dehydrogenation process is briefly introduced, and multi-effect distillation is proposed as the energy saving measure. Aspen Plus is used to simulate three processes of crude styrene tower, i.e. single distillation, parallel-flow double-effect distillation and mixed-flow double-effect distillation. The results show that the energy-saving effect of the parallel-flow double-effect distillation is remarkable, and the energy consumption is reduced by about 11%-12%.
Key words: styrene, energy consumption, energy conservation, double-effect distillation, simulation
Pei Jianing, Xu Yao, Guo Xiaoyuan. Energy Saving Optimization of Crude Styrene Tower[J].Petrochemical Design, 2019, 36(3): 64-.