固定床加氢反应器  ,反应器内件  ,分配盘  ,冷氢箱  ,出口收集器 ," /> 固定床加氢反应器  ,反应器内件  ,分配盘  ,冷氢箱  ,出口收集器 ,"/> fixed bed hydrogenation reactor,reactor internals,distribution disk,hydrogen cold box,outlet collector ,"/> <p class="MsoNormal"> <b><span>Problems in Installation of Internals in Fixed Bed Hydrogenation Reactors and the Solutions</span></b>

Petrochemical Design ›› 2024, Vol. 41 ›› Issue (2): 27-30.doi: 10.3969/j.issn.1005-8168.2024.02-006

Previous Articles     Next Articles

Problems in Installation of Internals in Fixed Bed Hydrogenation Reactors and the Solutions

Liu Xiaofeng   

  1. (SINOPEC Zhenhai Refining & Chemical Company, Ningbo, Zhejiang, 315200)

  • Received:2022-09-15 Online:2024-05-25 Published:2024-05-11

Abstract: This paper introduces the basic structure of fixed bed C5 diolefin hydrogenation reactor and the problems that a large number of internals cannot be installed during the installation of the equipment, analyzes in detail the problems in the installation of catalyst redistribution disk, main beam of hydrogen cold box and cold hydrogen injection disk, outlet collector and external insulation support ring of reactor, and puts forward some targeted solutions. After analyzing the causes of the problems, surveying and mapping the dimensions and taking targeted measures, the installation of reactor internals is successfully completed, and some control measures are proposed for the future installation of similar equipment internals from the aspects of equipment design, drawing review by engineers and pre assembly prior to installation, so as to solve the problems before actual installation.

Key words: fixed bed hydrogenation reactor')">

fixed bed hydrogenation reactor, reactor internals, distribution disk, hydrogen cold box, outlet collector