Petrochemical Design ›› 2018, Vol. 35 ›› Issue (3): 52-54.doi: 10.3969/j.issn.1005-8168.2018.03.015

• ENGINEERING AND APPLICATION • Previous Articles     Next Articles

Analysis and Relieving Calculation for Exchanger Tube Rupture

Zhang Jianhua   

  1. SINOPEC Engineering Incorporation, Beijing, 100101
  • Received:2018-01-02 Accepted:2018-05-15 Online:2018-08-25 Published:2018-09-01
  • Contact: Zhang Jianhua,zhangjh@sei.com.cn E-mail:zhangjh@sei.com.cn

Abstract: Exchanger tube rupture is a remote but possible contingency. It is difficult for calculating the relief flowrate, especially for vapor-liquid phase. This article analyzed the formula of this case and describes the calculation method of exchanger tube rupture case relief flowrate base on literature search and engineering experience

Key words: safety valve, heat transfer tube rupture, safety relief amount, two-phase flow